OVERVIEW
The report that follows has been
prepared from the perspective of what an owner of this property would benefit
from knowing. Thus, it discusses many
things beyond those which are of immediate concern. Therefore, the report needs to be read in its entirety to
understand fully all the information that has been obtained.
For your convenience, we have
prepared the following overview of the condition of the major systems of the
house. Please refer to the appropriate
section of this report for a more detailed discussion of these systems.
|
ITEM |
CONDITION1
|
REPAIRS |
TYPICAL?3 |
|
|||||||
|
|
0 |
1 |
2 |
3 |
4 |
5 |
NEEDED?2 |
|
|||
|
STRUCTURAL |
|
|
|
|
|||||||
|
Foundation |
|
SR |
+ |
|
|||||||
|
Framing |
|
SR |
ü |
|
|||||||
|
Porches/Decks |
|
SR |
ü |
|
|||||||
|
Outbuildings |
|
SR |
ü |
|
|||||||
|
EXTERIOR |
|
|
|
|
|||||||
|
Roofing |
|
|
|
|
|||||||
|
Chimney |
|
|
|
|
|||||||
|
Cladding |
|
SR |
- |
|
|||||||
|
ELECTRICAL |
|
|
|
|
|||||||
|
Capacity |
|
|
+ |
|
|||||||
|
Wiring |
|
SR |
+ |
|
|||||||
|
PLUMBING |
|
|
|
|
|||||||
|
Piping/Fixtures |
|
SR |
ü |
|
|||||||
|
Sewer |
|
SR |
ü |
|
|||||||
|
HEATING/AC |
|
|
|
|
|||||||
|
Unit(s) |
|
SR |
+ |
|
|||||||
|
Distribution |
|
SR |
ü |
|
|||||||
|
|
|
|
|
|
|||||||
|
INTERIOR |
|
SR |
ü |
|
|||||||
|
|
|
|
|
|
|||||||
|
SAFETY |
|
SR |
ü |
|
|||||||
|
|
|
|
|
|
|||||||
|
ENVIRONMENTAL |
|
SR |
ü |
|
|||||||
|
1 On a scale of 1
to 5, with 5 being best. 2 ü indicates repairs are
needed within the next year, SR
means SEE REPORT for more details. 3 ü indicates the component
and/or condition is typical for a
building of similar age and construction type, a positive
sign (+) indicates that it is
above average, and a negative sign
(-) indicates that it is below average. |
|
||||||||||
Corrective Work
Because of their
present condition and because of the cost of their repair or replacement, the
following are high priority items that will need your immediate attention:
|
PROBLEM
|
COST ESTIMATE |
|
1.
Repair and
replace clapboard siding, cornice trim, fascia, soffits, cornerboards, window
frames |
$4000 - $6000 |
|
2.
Caulk and
paint siding and trim |
$4000 |
|
3.
Align and
repair front porch |
$4000 - $8000 |
|
4.
Brace and
straighten bowed exterior wall |
$1000 - $3000 |
|
5.
Insulate
first floor area |
$1000 - $2000 |
|
6.
Insulate
heating/AC ducts |
$500 - $1000 |
|
7.
Install
GFCIs, repair ungrounded circuits, replace knob and tube wiring, add outlets,
check wiring |
$2000 - $3000 |
Further investigation
During our inspection we
were not able to fully evaluate the condition and/or operation of the following
items:
1. Moisture levels in
exterior wall cavities.
2. The sufficiency of the
heating system.
We recommend that these items be investigated further, before assuming
ownership of the property.
General Condition
Although this is an
older home, it has been constructed with quality materials and
workmanship. It is generally in good
condition. With attention to the items
mentioned in this report, this home
should offer many years of relatively trouble‑free occupancy.
INTRODUCTION
At
your request, a structural and mechanical inspection of the above property was
performed on September 19, 1996. The
report that follows has been prepared based on that inspection. The inspection was performed by and report
written by William A. Stanton, P.E.
Criterium
- Stanton Engineers offers two types of residential inspections; the Standard
Inspection and the Comprehensive Inspection.
Essentially, the Standard Inspection relies on visual evidence available
at the time of the inspection, while the Comprehensive Inspection relies on
visual evidence plus analysis, invasive testing, and extended, on-site
evaluation to reach its conclusions.
Further detail regarding these two types of inspections can be found in
Appendix D of this report.
Based
on discussions prior to our inspection, you have chosen the Standard
Inspection. Our inspection and the
report that follows were conducted in accordance with the Standard Inspection.
For your reference
while reading the report, the following definitions may be helpful:
|
Excellent - |
Component
or system is in “as new” condition requiring no rehabilitation and should
perform in accordance with expected performance. |
|
Good - |
Component
or system is sound and performing its function, although it may show signs of
normal wear and tear. Some minor
rehabilitation work may be required. |
|
Fair - |
Component
or system falls into one or more of the following categories: a) Evidence of previous repairs not in
compliance with commonly accepted practice, b) Workmanship not in compliance
with commonly accepted standards, c) Component or system is obsolete, d)
Component or system approaching end of expected performance. Repair or replacement is required to
prevent further deterioration or to prolong expected life. |
|
Poor - |
Component
or system has either failed or cannot be relied upon to continue performing
its original function as a result of having exceeded its expected
performance, excessive deferred maintenance, or state of disrepair. Present condition could contribute to or
cause the deterioration of other adjoining elements or systems. Repair or replacement is required. |
All ratings are determined
by comparison to other buildings of similar age and construction. Further, some details of workmanship and
materials will be examined more closely in higher quality home where such
details of workmanship and materials become more relevant.
Appendix C contains the actual inspection field notes which contain additional information. These should be considered part of the overall evaluati