CRITERIUM-STANTON ENGINEERS

Photos of Structural Defects

(Click on hyperlinked photo to enlarge)

Intersection of hip rafters and ridge. Note lack of vertical brace. Valley rafter and common rafters are unsupported. The 2x4 purlins require additional braces. Note how purlin bows under the rafter load.

Photo 10

Photo 11

Photo 12

General view of roof support system. Note lack of supports at midspans of rafters. The girder should be supported on a pilaster and not the curtain wall. Shrinkage crack in the basement floor. Usually this is not a structural concern.

Photo 13

Photo 14

Photo 15

This dry-laid brick pier does not provide much support. The bottom concrete block in the pier is not solidly supported. The pier supports a heavily loaded steel beam. The pier only catches the corner of the girder. Girder should be in the middle third of the pier. The outer girder ply is not supported by the pier.

Photo 16

Photo 17

Photo 18

Photo 19